Manufacturer Specifications:

The Fluke 114 is the troubleshooting tool for “go/no-go” testing. It includes a feature to prevent false readings caused by ghost voltage.


Features at a Glance:
  • True RMS
  • .5% Accuracy
  • 28% larger digits
  • 6000 counts
  • Bargraph
  • Backlight
  • Min-max recording
  • Display hold
  • Ergonomic, Compact Shape
  • LoZ (New!)
  • AutoV (New!)


 

Features:

  • AutoVolt automatic ac/dc voltage selection
  • Large white LED backlight to work in poorly lit areas
  • Resistance and continuity
  • Min/Max/Average to record signal fluctuations
  • CAT III 600 V safety rated



  Comparison Guide: 

 

  Current New
Basic features 110 111 112 12 16 114 115 116 117
True RMS readings AC AC AC     AC AC AC AC
Basic DC accuracy 0.7% 0.7% 0.7% 0.9% 0.9% 0.5% 0.5% 0.5% 0.5%
Digits 3-1/2 3-1/2 3-1/2 3-1/2 3-1/2 3-1/2 3-1/2 3-1/2 3-1/2
Counts 6000 6000 6000 4000 4000 6000 6000 6000 6000
Measurements
Voltage AC/DC 600V 600V 600V 600V 600V 600V 600V 600V 600V
Current AC/DC   10A 10A   200µA   10A 600µA 10A
Resistance 40MO 40MO 40MO 40MO 40MO 40MO 40MO 40MO 40MO
Frequency 50kHz 50kHz 50kHz       50kHz 50kHz 50kHz
Capacitance 10mF 10mF 10mF 10mF 10mF   10mF 10mF 10mF
Temperature         +400°C     +400°C  
Display
Analog bargraph    
Backlight        
Data storage and exchange
Min-Max recording  
Display Hold/Auto (Touch) Hold    
Other features
Automatic selection, VChek              
Automatic selection, LoZ            
Volt Alert, Non Contact ac voltage detector                


 

General specifications:

     Accuracy is specified for 1 year after calibration, at operating temperatures of 18 °C to 28 °C, with relative humidity at 0 % to 95 %. 
The accuracy specifications take the form of: ± ( [ % of Reading ] + [ Counts ] )


Maximum voltage between any terminal and earth ground 600 V
Surge protection 6 kV peak per IEC 61010-1 600 V CAT III, Pollution Degree 2
Display Digital: 6,000 counts, updates 4/sec
Bar graph 33 segments, updates 32/sec
Operating temperature -10 °C to + 50 °C
Storage temperature -40 °C to + 60 °C
Battery 9 volt Alkaline, NEDA 1604A/IEC 6LR61
Battery life 400 hours typical, without backlight


Measurement Range Resolution Accuracy ± ([% of reading] + [counts])
DC millivolts 600.0 mV 0.1 mV 2.0 % + 3
DC volts 6.000 V 0.001 V  
60.00 V 0.01 V
600.0 V 0.1 V
Auto volts 600.0 V 0.1 V 2.0 % + 3 (dc, 45 Hz to 500 Hz)
4.0 % + 3 (500 Hz to 1 kHz)
AC millivolts1 true-rms 600.0 mV 0.1 mV 1.0 % + 3 (dc, 45 Hz to 500 Hz)
2.0 % + 3 (500 Hz to 1 kHz)
AC volts1 true-rms 6.000 V 0.001 V 1.0 % + 3 (dc, 45 Hz to 500 Hz)
2.0 % + 3 (500 Hz to 1 kHz)
60.00 V 0.01 V
600.0 V 0.1 V
Continuity 600 W 1 W Beeper on < 20 W, off > 250 W; detects opens or shorts of 500 µs or longer.
Ohms 600.0 W 0.1 W 0.9 % + 2
6.000 kW 0.001 kW 0.9 % + 1
60.00 kW 0.01 kW
600.0 kW 0.1 kW
6.000 MW 0.001 MW
40.00 MW 0.01 MW 1.5 % + 2

1 All ac voltage ranges are specified from 1 % to 100% of range. Because inputs below 1 % of range are not specified, it is normal for this and other true-rms meters to display non-zero readings when the test leads are disconnected from a circuit or are shorted together. For volts, crest factor of = 3 at 4000 counts, decreasing linearly to 1.5 at full scale. AC volts is ac-coupled. Auto-V LoZ, and ac mV are dc-coupled.

Write a Review

Tell us what you think about this item and share your opinions with other people. Please make sure your review focuses only on this item. All reviews are moderated and will be reviewed within two business days. Inappropriate reviews will not be posted.

After-sales questions and issues: Contact our Customer Service Department. (A customer representative will get back to you).

Please Sign In first if you want to later edit or manage reviews uploaded by yourself.

* Rating:
    Please select rating stars.
* Your First & Last Name:
* Your E-Mail Address:
* Review Title:
* Review Detail:
Newsletter
Stay Tuned!
Get updates on sales and discount offers.