Atten Spectrum Analyzer AT 5011A
Item No.:AT 5011A
Atten Spectrum AnalyzerAT 5011A
Quantity :
Add to Shopping Cart
Manufacturer Specifications:

Spectrum Analyzer ( AT 5000 Series)


Model: AT 5011A with tracking generator

      

      AT5000 series spectrum analyzer will exceed 1Ghz(0.15~1050MHz) have the glancing or fine adjust center frequency with the 100KHz/grid~100MHz/grid span select, compose the simple frequency-domain. One 4 and 1/2 bit LED display can be selected for the center frequency and marking frequency reading.AT5011A have a tracking generator, this instrument can be used to the pre-research testing. can detect the mobile phone’s RF circuit’s native signal, intermediate frequency, radiation signal etc. the spectrum analyzer is used to examine and repaired that mobile phone can’t going the web, very conveniently and exactly.

 

 

§          Frequency range: 0.15~1050MHz

§          4 and 1/2 digital displays. (Center frequency, 0.1MHz resolution)

§          -100~+13dBm amplitude range, 20MHz, 400MHz center frequency span and 4 KHz video filter.

§          Tracking generator

§          Output amplitude :+0~-50dBm(50Ω)

§          Specifications:

§          Frequency range:  0.15 to 1050MHz          

§          Center frequency display accuracy: ±100kHz

§          Marker accuracy: 0.1% spans 100 kHz       

§          Resolution of frequency display: 100 kHz (4.5 digit LED)

§          Frequency scans width accuracy: ±10%       

§          Frequency stability: better than 150 kHz/ hour

§          IF Bandwidth (-3dB): 400 kHz and 20 kHz;    

§          Video-Filter (ON): 4 kHz

§          Sweep rate:  43Hz                          

§          Amplitude range: -100dBm to +13dBm

§          Screen display range: 80dB (10dB/div.)     

§          Reference level: -27dBm to +13dBm (in 10dB steps)

§          Reference level accuracy: ±2dB            

§          Average noise level: -90dBm (20 kHz Bandwidth)

§          Distortion: < -55dBc of 2nd and 3rd harmonic   

§          Third order intermod.: -70dBc (two signals > 3MHz apart)

§          Sensitivity: Better than -90dBm             

§          Log scale fidelity: ±2dB (without attn.) 500MHz

§          Input attenuator: 0 to 40dB (4×10dB steps)  

§          Input attenuator accuracy: ±1dB/10dB

§          Max. Input level: +10dBm, ±25V DC (0dB attn.) +20dBm (40dB attn.)

§          Frequency scans width: 100 kHz/div. to 100MHz/div, in 1-2-5 steps and 0Hz/div. (Zero Scan)

Write a Review

Tell us what you think about this item and share your opinions with other people. Please make sure your review focuses only on this item. All reviews are moderated and will be reviewed within two business days. Inappropriate reviews will not be posted.

After-sales questions and issues: Contact our Customer Service Department. (A customer representative will get back to you).

Please Sign In first if you want to later edit or manage reviews uploaded by yourself.

* Rating:
    Please select rating stars.
* Your First & Last Name:
* Your E-Mail Address:
* Review Title:
* Review Detail:
Newsletter
Stay Tuned!
Get updates on sales and discount offers.