8.4 inch Patient monitor SPO2/ECG/NIBP
Item No.:CMS6000
8.4” color TFT display
Unique digital SPO technology with excellent measurement and interference-free
Audible and visual alarms with adjustable alarm range
Anti electrosurgical interference and defibrillation
Can be connected with LAN to work with central monitoring system
Powerful data management and storage capacity
Suitable for adult, pediatric and neonatal patient
Quantity :
Add to Shopping Cart
Manufacturer Specifications:

Features:            

  • 8.4” color TFT display
  • Unique digital SPO technology with excellent measurement and interference-free
  • Audible and visual alarms with adjustable alarm range
  • Anti electrosurgical interference and defibrillation
  • Can be connected with LAN to work with central monitoring system
  • Powerful data management and storage capacity
  • Suitable for adult, pediatric and neonatal patient

Standard configuration:            

  • ECG, NIBP, SPO2, PR, Built-in rechargeable battery

Optional:            

  • RESP, TEMP, 2-TEMP, 2-IBP, ETCO2, Thermal printer

 

Technical Specifications:

ECG:            

  • Lead Mode: 5 Leads (R, L, F, N, C or RA, LA, LL, RL, V)
  • Lead selection: I, II, III, avR, avL, avF, V
  • Waveform: 2 ch
  • Gain: 2.5mm/mV, 5.0mm/mV, 10mm/mV, 20mm/mV
  • HR and Alarm Range:
    Adult: 15 ~ 300 bpm
    Neo/Ped: 15 ~ 350 bpm
    Accuracy: ±1% or ±1bpm, which great
    Resolution: 1 bpm
    Sensitivity: >200uV P-P
  • Differential Input Impedance: >5MΩ
  • CMRR:
    Monitor: >105dB
    Operation: >105dB
    Diagnosis: >85dB
  • Electrode offset potential: 300mV
  • Leakage Current: <10uA
  • Baseline Recovery: <3s after Defi.
  • ECG Signal Range: 8mV(Vp-p)
  • Calibration Signal: 1mV (Vp-p), 5% Accuracy
  • ST Segment measure and alarm: -2.0 ~ +2.0 mV

NIBP:            

  • Method: Oscillometry
  • Mode: Manual, Auto, STAT
  • Measuring Interval in AUTO Mode: 1, 2, 3, 4, 5, 10, 15, 30, 60, 90Min
  • Measuring Period in STAT Mode: 5 Min
  • Pulse Rate Range: 40 ~ 240 bpm
  • Alarm Type: SYS, DIA, MEAN
  • Measuring and alarm Range
    Adult Mode:
    SYS: 40 ~ 270 mmHg
    DIA: 10 ~ 215 mmHg
    MEAN: 20 ~ 235 mmHg
    Pediatric Mode
    SYS: 40 ~ 200 mmHg
    DIA: 10 ~ 150 mmHg
    MEAN: 20 ~ 165 mmHg
    Neonatal Mode
    SYS: 40 ~ 135 mmHg
    DIA: 10 ~ 100 mmHg
    MEAN: 20 ~ 110 mmHg
    Resolution: 1mmHg
  • Over-pressure protection: YES

SPO2:            

  • Measuring Range: 0 ~ 100%
  • Alarm Range: 0 ~ 100%
  • Resolution: 1%
  • Accuracy:
    70% ~ 100%: 2 %
    0% ~ 69%: unspecified
  • Actualization interval: About 1Sec.
  • Alarm Delay: 10 Sec.
  • Pulse Rate
    Measuring and Alarm Range: 0~254bpm
    Resolution: 1bpm
    Accuracy: 2bpm
    Alarm Delay: 10 Sec.
Write a Review

Tell us what you think about this item and share your opinions with other people. Please make sure your review focuses only on this item. All reviews are moderated and will be reviewed within two business days. Inappropriate reviews will not be posted.

After-sales questions and issues: Contact our Customer Service Department. (A customer representative will get back to you).